{"id":7150,"date":"2025-03-03T05:20:08","date_gmt":"2025-03-03T05:20:08","guid":{"rendered":"https:\/\/www.forethoughtmed.com\/?p=7150"},"modified":"2025-03-14T02:23:12","modified_gmt":"2025-03-14T02:23:12","slug":"sci-essay-from-ruijin-hospital","status":"publish","type":"post","link":"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/","title":{"rendered":"Essai sur le PCD de l'h\u00f4pital Ruijin"},"content":{"rendered":"<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" width=\"840\" height=\"629\" src=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/blog-2.jpg\" alt=\"Essai sur le PCD de l&#039;h\u00f4pital Ruijin\" class=\"wp-image-7331\" style=\"width:840px\" srcset=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/blog-2.jpg 840w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/blog-2-534x400.jpg 534w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/blog-2-768x575.jpg 768w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/blog-2-16x12.jpg 16w\" sizes=\"(max-width: 840px) 100vw, 840px\" \/><\/figure><div id=\"ez-toc-container\" class=\"ez-toc-v2_0_74 counter-hierarchy ez-toc-counter ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table des mati\u00e8res\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#A_novel_portable_and_radiation-free_method_for_assessing_scoliosis_an_accurate_and_reproducible_study\" >Une nouvelle m\u00e9thode portable et sans rayonnement pour \u00e9valuer la scoliose : une \u00e9tude pr\u00e9cise et reproductible<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Abstract\" >R\u00e9sum\u00e9<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Background\" >Contexte<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Methods\" >M\u00e9thodes<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Study_population\" >Population de l'\u00e9tude<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#EOS_imaging_and_3D_reconstruction\" >Imagerie EOS et reconstruction 3D<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Examination_with_3D-SSS\" >Examen avec 3D-SSS<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Statistical_analysis\" >Analyse statistique<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Results\" >R\u00e9sultats<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Discussion\" >Discussion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Conclusions\" >Conclusions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Abbreviations\" >Abr\u00e9viations<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Acknowledgements\" >Remerciements<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Author_Contributions\" >Contributions des auteurs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Author_information\" >Informations sur l'auteur<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Funding\" >Financement<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Data_availability\" >Disponibilit\u00e9 des donn\u00e9es<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Declarations\" >D\u00e9clarations<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Ethics_approval_and_consent_to_participate\" >Approbation \u00e9thique et consentement \u00e0 la participation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Consent_for_publication\" >Consentement \u00e0 la publication<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Competing_interests\" >Int\u00e9r\u00eats concurrents<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#References\" >R\u00e9f\u00e9rences<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"http:\/\/www.forethoughtmed.com\/fr\/sci-essay-from-ruijin-hospital\/#Publishers_note\" >Note de l'\u00e9diteur<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"A_novel_portable_and_radiation-free_method_for_assessing_scoliosis_an_accurate_and_reproducible_study\"><\/span><strong>Une nouvelle m\u00e9thode portable et sans rayonnement pour \u00e9valuer la scoliose : une \u00e9tude pr\u00e9cise et reproductible<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p><sup>Hui Wang1, Yunfeng Zhu1, Qiyuan Bao2, Yong Lu1, Fuhua Yan1, Lianjun Du1 et Le Qin1*.<\/sup><\/p><h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Abstract\"><\/span><strong>R\u00e9sum\u00e9<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p><strong>Contexte<\/strong> Cette \u00e9tude visait \u00e0 \u00e9valuer la pr\u00e9cision et la reproductibilit\u00e9 d'un syst\u00e8me de d\u00e9tection tridimensionnelle de la colonne vert\u00e9brale (3D-SSS) r\u00e9cemment mis au point, portable et sans rayonnement, pour l'\u00e9valuation de la scoliose.<\/p><p><strong>M\u00e9thodes<\/strong> Au total, 145 patients ont subi une imagerie de la colonne vert\u00e9brale compl\u00e8te \u00e0 l'aide du syst\u00e8me d'imagerie EOS, et les donn\u00e9es 3D-SSS ont \u00e9t\u00e9 collect\u00e9es entre f\u00e9vrier 2023 et avril 2023. Un radiologue a utilis\u00e9 le logiciel sterEOS pour reconstruire la colonne vert\u00e9brale en 3D et obtenir l'angle de Cobb. Un radiologue et un orthop\u00e9diste ont mesur\u00e9 ind\u00e9pendamment les patients \u00e0 l'aide de 3D-SSS, l'orthop\u00e9diste effectuant deux mesures par patient. Le syst\u00e8me de post-traitement 3D-SSS a g\u00e9n\u00e9r\u00e9 automatiquement l'angle de Cobb.<\/p><p><strong>R\u00e9sultats<\/strong> Les angles de Cobb moyens obtenus par EOS et 3D-SSS \u00e9taient respectivement de 13,7 \u00b1 9,9\u00b0 (0,5\u223d45,7\u00b0) et de 12,5 \u00b1 8,6\u00b0 (0,4\u223d40\u00b0). Le coefficient de corr\u00e9lation intraclasse (ICC) pour la fiabilit\u00e9 entre l'EOS et le 3D-SSS \u00e9tait de 0,921, ce qui indique une excellente concordance. L'analyse de Bland-Altman a r\u00e9v\u00e9l\u00e9 un biais de -1,171\u00b0 entre l'EOS et le 3D-SSS, avec seulement 10 patients en dehors des limites de la concordance (-8,3\u223d6,0\u00b0). L'erreur quadratique moyenne entre l'EOS et le 3D-SSS \u00e9tait de 3,2\u00b0. Une forte corr\u00e9lation a \u00e9t\u00e9 observ\u00e9e entre les angles de Cobb mesur\u00e9s par EOS et 3D-SSS (<em>r<\/em>= 0.931,&nbsp;<em>P<\/em>&lt; 0.001). La courbe des caract\u00e9ristiques d&#039;exploitation du r\u00e9cepteur a montr\u00e9 que la performance diagnostique du 3D-SSS pour la scoliose \u00e9tait de 0,953 (<em>P<\/em>&lt; 0.001). La sensibilit\u00e9, la sp\u00e9cificit\u00e9, la valeur pr\u00e9dictive positive et la valeur pr\u00e9dictive n\u00e9gative de la 3D-SSS pour le diagnostic de la scoliose \u00e9taient respectivement de 87,8%, 92,1%, 93,5% et 85,3%. Les ICC intra-observateur et inter-observateur pour les angles de Cobb d\u00e9riv\u00e9s du 3D-SSS \u00e9taient respectivement de 0,969 et 0,934, ce qui d\u00e9montre une excellente reproductibilit\u00e9.<\/p><p><strong>Conclusions<\/strong> Le 3D-SSS portable et sans rayonnement a mesur\u00e9 avec pr\u00e9cision la scoliose et a fourni des donn\u00e9es hautement reproductibles. Ce syst\u00e8me offre aux cliniciens une nouvelle m\u00e9thode de d\u00e9pistage et de suivi de la scoliose chez les jeunes patients.<\/p><p><strong>Mots cl\u00e9s<\/strong> Scoliose, portable, sans rayonnement, syst\u00e8me de d\u00e9tection tridimensionnelle de la colonne vert\u00e9brale, angle de Cobb<\/p><figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" width=\"811\" height=\"273\" src=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65872-2.png\" alt=\"\" class=\"wp-image-7232\" style=\"width:840px;height:auto\" srcset=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65872-2.png 811w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65872-2-800x269.png 800w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65872-2-768x259.png 768w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65872-2-18x6.png 18w\" sizes=\"(max-width: 811px) 100vw, 811px\" \/><\/figure><h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Background\"><\/span><strong>Contexte<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p>La scoliose est une d\u00e9formation tridimensionnelle (3D) de la colonne vert\u00e9brale impliquant les plans coronal, sagittal et transversal [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR1\" rel=\"nofollow noopener\" target=\"_blank\">1<\/a>]. L'\u00e9tiologie de la scoliose est multifactorielle, impliquant la g\u00e9n\u00e9tique, la biom\u00e9canique de la colonne vert\u00e9brale, la neurologie et la biochimie [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR2\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>]. Une th\u00e9orie neurologique importante sugg\u00e8re qu'un mauvais contr\u00f4le de l'\u00e9quilibre postural d\u00fb \u00e0 une alt\u00e9ration de la fonction vestibulaire contribue \u00e0 sa pathogen\u00e8se [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR2\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR3\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>]. D'un point de vue biochimique, une faible densit\u00e9 min\u00e9rale osseuse peut augmenter le stress et acc\u00e9l\u00e9rer la progression de la courbe dans la scoliose [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR2\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR4\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a>]. Le type le plus courant est la scoliose idiopathique de l'adolescent (SIA), qui survient entre 11 et 18 ans, avec une incidence globale de 0,47-5,2% [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR2\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR5\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a>]. La scoliose idiopathique de l'adulte chez les patients de moins de 40 ans \u00e9volue souvent \u00e0 partir d'un SIA non trait\u00e9 [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR6\" rel=\"nofollow noopener\" target=\"_blank\">6<\/a>]. Sur le plan clinique, les SIA graves peuvent entra\u00eener une apparence anormale, une cage thoracique asym\u00e9trique, une alt\u00e9ration de la fonction cardiopulmonaire ou une compression de la moelle \u00e9pini\u00e8re [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR7\" rel=\"nofollow noopener\" target=\"_blank\">7<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR8\" rel=\"nofollow noopener\" target=\"_blank\">8<\/a>]. Le diagnostic pr\u00e9coce et l'\u00e9valuation de la gravit\u00e9 de l'AIS sont donc essentiels.<\/p><p>L'imagerie radiologique est couramment utilis\u00e9e pour mesurer l'angle de Cobb et \u00e9valuer le plan coronal dans les SIA. Historiquement, l'imagerie de la colonne vert\u00e9brale compl\u00e8te \u00e9tait obtenue en combinant plusieurs radiographies \u00e0 rayons X, ce qui entra\u00eenait une distorsion de l'image et une exposition importante aux radiations pour les patients. Avec les progr\u00e8s de la technologie d'imagerie, le syst\u00e8me d'imagerie EOS a \u00e9t\u00e9 introduit pour \u00e9valuer les d\u00e9formations de la colonne vert\u00e9brale [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR9\" rel=\"nofollow noopener\" target=\"_blank\">9<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR10\" rel=\"nofollow noopener\" target=\"_blank\">10<\/a>]. L'EOS offre des avantages tels qu'une faible dose de rayonnement, la possibilit\u00e9 de capturer des images biplanaires de l'ensemble du corps en position debout et la capacit\u00e9 de reconstruire des images en 3D [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR11\" rel=\"nofollow noopener\" target=\"_blank\">11<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR12\" rel=\"nofollow noopener\" target=\"_blank\">12<\/a>]. Cependant, l'EOS pr\u00e9sente plusieurs limites, notamment la complexit\u00e9 de son fonctionnement, l'exposition aux rayonnements ionisants, les co\u00fbts initiaux \u00e9lev\u00e9s et l'immobilit\u00e9 de l'\u00e9quipement, ce qui le rend inadapt\u00e9 au d\u00e9pistage \u00e0 grande \u00e9chelle et peu pratique pour les suivis [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR13\" rel=\"nofollow noopener\" target=\"_blank\">13<\/a>].<\/p><p>Pour relever ces d\u00e9fis, un nouveau syst\u00e8me de d\u00e9tection 3D de la colonne vert\u00e9brale (3D-SSS) portable et sans rayonnement a \u00e9t\u00e9 mis au point, offrant une alternative \u00e0 l'imagerie par rayons X pour l'\u00e9valuation des param\u00e8tres de la scoliose. Le 3D-SSS est con\u00e7u pour un d\u00e9pistage approfondi de la scoliose et des examens cliniques plus rapides. Il utilise la technologie de mesure de la trajectoire de l'espace de contact et un capteur de syst\u00e8me micro-\u00e9lectrom\u00e9canique (MEMS) pour mesurer les angles spatiaux au cours d'un mouvement dynamique. Combin\u00e9 \u00e0 la mesure de la distance de trajectoire, le syst\u00e8me g\u00e9n\u00e8re les coordonn\u00e9es de la courbe vectorielle spatiale de l'apophyse \u00e9pineuse dorsale [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR14\" rel=\"nofollow noopener\" target=\"_blank\">14<\/a>]. En int\u00e9grant les donn\u00e9es de balayage du terrain provenant d'un capteur de balancier d'\u00e9quipement et en cartographiant num\u00e9riquement ces coordonn\u00e9es sur un mod\u00e8le 3D standard de la colonne vert\u00e9brale, un v\u00e9ritable mod\u00e8le num\u00e9rique 3D de la colonne vert\u00e9brale peut \u00eatre construit [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR15\" rel=\"nofollow noopener\" target=\"_blank\">15<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR16\" rel=\"nofollow noopener\" target=\"_blank\">16<\/a>]. Les param\u00e8tres rachidiens sont ensuite calcul\u00e9s dans le plan coronal \u00e0 l'aide d'un algorithme math\u00e9matique. Malgr\u00e9 son potentiel, l'utilit\u00e9 clinique du 3D-SSS reste incertaine.<\/p><p>La pr\u00e9sente \u00e9tude visait \u00e0 \u00e9valuer la pr\u00e9cision et la reproductibilit\u00e9 des mesures de l'angle de Cobb obtenues \u00e0 l'aide du 3D-SSS chez des patients suspect\u00e9s de scoliose.<\/p><h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Methods\"><\/span><strong>M\u00e9thodes<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><h3 class=\"wp-block-heading\" id=\"Sec3\"><span class=\"ez-toc-section\" id=\"Study_population\"><\/span><strong>Population de l'\u00e9tude<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>Cette \u00e9tude prospective a \u00e9t\u00e9 approuv\u00e9e par le comit\u00e9 d'\u00e9thique de l'\u00e9tablissement et tous les participants ont fourni un consentement \u00e9clair\u00e9 sign\u00e9. Entre f\u00e9vrier 2023 et avril 2023, 183 personnes cons\u00e9cutives ont \u00e9t\u00e9 recrut\u00e9es sur la base des crit\u00e8res d'inclusion suivants : (1) suspicion de scoliose ; (2) \u00e2ge inf\u00e9rieur \u00e0 40 ans ; (3) imagerie de la colonne vert\u00e9brale compl\u00e8te \u00e0 l'aide du syst\u00e8me d'imagerie EOS (imagerie EOS). Les crit\u00e8res d'exclusion \u00e9taient les suivants (1) peau du dos bless\u00e9e ou sensible ; (2) utilisation d'appareils orthop\u00e9diques ; (3) incapacit\u00e9 \u00e0 se tenir debout pendant l'examen EOS ; (4) pr\u00e9sence de fractures vert\u00e9brales ou de tumeurs. Sur la base de ces crit\u00e8res, 38 patients ont \u00e9t\u00e9 exclus, laissant un total de 145 patients pour l'analyse (Fig.&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Fig1\" rel=\"nofollow noopener\" target=\"_blank\">1<\/a>).<\/p><figure class=\"wp-block-image\"><a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3\/figures\/1\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/media.springernature.com\/lw685\/springer-static\/image\/art%3A10.1186%2Fs12891-025-08415-3\/MediaObjects\/12891_2025_8415_Fig1_HTML.png\" alt=\"figure 1\"\/><\/a><figcaption class=\"wp-element-caption\"><strong>Fig. 1<\/strong> Organigramme de la s\u00e9lection des patients<\/figcaption><\/figure><h3 class=\"wp-block-heading\" id=\"Sec4\"><span class=\"ez-toc-section\" id=\"EOS_imaging_and_3D_reconstruction\"><\/span><strong>Imagerie EOS et reconstruction 3D<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>Les patients se tenaient au centre de la zone d'examen en position ant\u00e9ro-post\u00e9rieure, les mains plac\u00e9es devant la t\u00eate. Deux images, coronale et sagittale, ont \u00e9t\u00e9 prises simultan\u00e9ment de la t\u00eate au f\u00e9mur. Ensuite, un radiologue a effectu\u00e9 une reconstruction 3D ind\u00e9pendante \u00e0 l'aide du logiciel sterEOS en mode \"Fast 3D\" : (1) La ligne sacr\u00e9e oblique a \u00e9t\u00e9 identifi\u00e9e, et la position ac\u00e9tabulaire et l'inclinaison pelvienne ont \u00e9t\u00e9 ajust\u00e9es sur les images coronales et sagittales. (2) La courbure de la colonne vert\u00e9brale (T1-L5) a \u00e9t\u00e9 d\u00e9termin\u00e9e et la largeur de la courbure a \u00e9t\u00e9 ajust\u00e9e pour correspondre \u00e0 une vert\u00e8bre. (3) Le logiciel a g\u00e9n\u00e9r\u00e9 automatiquement un mod\u00e8le pour chaque corps vert\u00e9bral, qui a ensuite \u00e9t\u00e9 ajust\u00e9 manuellement pour aligner la lame terminale, l'apophyse \u00e9pineuse et le p\u00e9dicule de l'arc vert\u00e9bral. (4) Les vert\u00e8bres apicales, sup\u00e9rieures et inf\u00e9rieures de l'angle de Cobb ont \u00e9t\u00e9 identifi\u00e9es manuellement et ajust\u00e9es avec pr\u00e9cision. Une fois la reconstruction 3D termin\u00e9e, le logiciel a calcul\u00e9 automatiquement l'angle de Cobb. Le SIA a \u00e9t\u00e9 d\u00e9fini comme un angle de Cobb \u2265 10\u00b0. Sur la base des recommandations de traitement, les angles de Cobb ont \u00e9t\u00e9 class\u00e9s en trois cat\u00e9gories : 10\u223d25\u00b0 (observation), 25\u223d45\u00b0 (attelle) et &gt; 45\u00b0 (chirurgie).<\/p><p>Les mesures ont \u00e9t\u00e9 effectu\u00e9es par un radiologue ayant dix ans d'exp\u00e9rience en radiologie musculo-squelettique \u00e0 l'aide du logiciel sterEOS.<\/p><h3 class=\"wp-block-heading\" id=\"Sec5\"><span class=\"ez-toc-section\" id=\"Examination_with_3D-SSS\"><\/span>Examen avec 3D-SSS<span class=\"ez-toc-section-end\"><\/span><\/h3><p>Le nouveau syst\u00e8me 3D-SSS (version : FT07W, Forethought<sup>\u00ae<\/sup>&nbsp;Spine Data Acquisition and Analysis System, Forethought [Shanghai] Medical Technology Co., Ltd, Shanghai, Chine) comprend un dispositif de balayage et un ordinateur portable de post-traitement. Le dispositif de balayage comprend un bo\u00eetier, un interrupteur, un indicateur \u00e0 diode \u00e9lectroluminescente (DEL), un rouleau sensible \u00e0 la lumi\u00e8re et quatre rouleaux d'\u00e9quilibrage \u00e0 l'ext\u00e9rieur (Fig.&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>). Il contient un module de capteur MEMS, un encodeur opto\u00e9lectronique, une carte m\u00e8re, une batterie et un module Bluetooth. L'analyse des donn\u00e9es et les mesures de la scoliose sont effectu\u00e9es \u00e0 l'aide d'un logiciel sur l'ordinateur portable. Le module de capteur MEMS combine un gyroscope \u00e0 3 axes, un acc\u00e9l\u00e9rom\u00e8tre \u00e0 3 axes et un capteur g\u00e9omagn\u00e9tique \u00e0 3 axes, ce qui permet de mesurer en temps r\u00e9el la vitesse de rotation et l'acc\u00e9l\u00e9ration.<\/p><p>Lorsque le dispositif de balayage se d\u00e9place le long de la colonne vert\u00e9brale, les quatre rouleaux d'\u00e9quilibrage veillent \u00e0 ce que le dispositif reste tangent \u00e0 la colonne vert\u00e9brale. Le module de capteur MEMS d\u00e9tecte les changements d'acc\u00e9l\u00e9ration et de vitesse angulaire en trois dimensions (X, Y et Z). Le microcontr\u00f4leur de la carte m\u00e8re (MCU) convertit les donn\u00e9es d'acc\u00e9l\u00e9ration et de vitesse angulaire en donn\u00e9es de quaternions, couramment utilis\u00e9es dans le suivi des mouvements en 3D. Les donn\u00e9es de quaternion sont temporairement stock\u00e9es dans la m\u00e9moire vive du MCU et sont transmises au logiciel de l'ordinateur portable via le module Bluetooth une fois la mesure termin\u00e9e. Le logiciel de l'ordinateur portable traite les donn\u00e9es de mouvement et calcule l'angle de Cobb.<\/p><p>Les \u00e9tapes d'utilisation du dispositif de d\u00e9tection de la scoliose sont les suivantes :<\/p><ul class=\"wp-block-list\"><li>(1) Le patient se tient debout, les genoux droits et les pieds plac\u00e9s \u00e0 la verticale, le visage tourn\u00e9 vers l'avant, tout en portant des v\u00eatements fins pour garantir la pr\u00e9cision des mesures.<\/li>\n\n<li>(2) L'op\u00e9rateur se place derri\u00e8re le patient et place le rouleau photosensible de l'appareil au niveau de la vert\u00e8bre C7, en appuyant l\u00e9g\u00e8rement les balanciers contre le dos du patient.<\/li>\n\n<li>(3) L'op\u00e9rateur clique sur le bouton \"START\" du logiciel de l'ordinateur portable et attend que l'indicateur LED devienne vert.<\/li>\n\n<li>(4) L'op\u00e9rateur d\u00e9place l'appareil le long de la colonne vert\u00e9brale du patient, de T1 \u00e0 L5 (Fig.&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Fig2\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>). Pendant le mouvement, le voyant lumineux clignote r\u00e9guli\u00e8rement. Les balanciers restent en contact avec les v\u00eatements du patient, tandis que l'op\u00e9rateur s'assure avec deux doigts que le rouleau opto\u00e9lectrique reste en contact avec les processus vert\u00e9braux.<\/li>\n\n<li>(5) Lorsque le niveau L5 est atteint, l'appareil est maintenu immobile pendant environ 2 s, ce qui permet \u00e0 l'indicateur LED d'arr\u00eater de clignoter. Le processus de mesure est alors termin\u00e9.<\/li>\n\n<li>(6) L'appareil transmet les donn\u00e9es de mesure au logiciel de l'ordinateur portable, qui affiche les r\u00e9sultats du test dans un d\u00e9lai de 3 \u00e0 10 s (Fig.&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Fig3\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>).<\/li><\/ul><figure class=\"wp-block-image\"><a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3\/figures\/2\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/media.springernature.com\/lw685\/springer-static\/image\/art%3A10.1186%2Fs12891-025-08415-3\/MediaObjects\/12891_2025_8415_Fig2_HTML.png\" alt=\"figure 2\"\/><\/a><figcaption class=\"wp-element-caption\"><strong>Fig. 2<\/strong> Illustration et fonctionnement de 3D-SSS. (<strong>A<\/strong>) Bo\u00eetier, interrupteur et indicateur LED de l'appareil ; (<strong>B<\/strong>) Un rouleau photosensible et quatre rouleaux d'\u00e9quilibrage de l'appareil ; (<strong>C<\/strong>) L'op\u00e9rateur d\u00e9place l'appareil le long de la colonne vert\u00e9brale du patient, de T1 \u00e0 L5.<\/figcaption><\/figure><p><strong>Fig. 3<\/strong> Reconstruction du mod\u00e8le 3D de la colonne vert\u00e9brale et calcul de l'angle de Cobb par 3D-SSS<\/p><figure class=\"wp-block-image\"><a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3\/figures\/3\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/media.springernature.com\/lw685\/springer-static\/image\/art%3A10.1186%2Fs12891-025-08415-3\/MediaObjects\/12891_2025_8415_Fig3_HTML.png\" alt=\"figure 3\"\/><\/a><\/figure><p><strong>Tableau 1 <\/strong>Donn\u00e9es d\u00e9mographiques des 145 patients<\/p><figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" width=\"1400\" height=\"136\" src=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65873-1400x136.png\" alt=\"\" class=\"wp-image-7216\" style=\"width:690px;height:auto\" srcset=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65873-1400x136.png 1400w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65873-800x78.png 800w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65873-768x75.png 768w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65873-1536x149.png 1536w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65873-18x2.png 18w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65873-1000x97.png 1000w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65873.png 1565w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><\/figure><p>Les sujets ont \u00e9t\u00e9 mesur\u00e9s ind\u00e9pendamment par deux m\u00e9decins : un radiologue ayant six ans d'exp\u00e9rience en radiologie musculo-squelettique et un orthop\u00e9diste ayant dix ans d'exp\u00e9rience en chirurgie de la colonne vert\u00e9brale. L'orthop\u00e9diste a effectu\u00e9 deux mesures sur chaque sujet. Les deux m\u00e9decins n'ont pas \u00e9t\u00e9 inform\u00e9s des r\u00e9sultats obtenus par EOS.<\/p><h3 class=\"wp-block-heading\" id=\"Sec6\"><span class=\"ez-toc-section\" id=\"Statistical_analysis\"><\/span><strong>Analyse statistique<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>Les param\u00e8tres quantitatifs ont \u00e9t\u00e9 exprim\u00e9s en moyenne \u00b1 \u00e9cart-type. Le coefficient de corr\u00e9lation intraclasse (ICC) a \u00e9t\u00e9 calcul\u00e9 pour \u00e9valuer la variabilit\u00e9 intra- et interobservateurs des mesures 3D-SSS. Les valeurs ICC ont \u00e9t\u00e9 interpr\u00e9t\u00e9es comme suit : &gt;0,8 (excellent), 0,6-0,8 (bon), 0,4-0,6 (mod\u00e9r\u00e9), 0,2-0,4 (l\u00e9ger), et &lt; 0,2 (mauvaise fiabilit\u00e9). L&#039;accord, la fiabilit\u00e9 et la corr\u00e9lation entre les mesures de l&#039;EOS et du 3D-SSS ont \u00e9t\u00e9 \u00e9valu\u00e9s \u00e0 l&#039;aide de l&#039;analyse de Bland-Altman, de l&#039;erreur quadratique moyenne (RMSE), de l&#039;ICC et du coefficient de corr\u00e9lation de Pearson, respectivement. L&#039;analyse statistique a \u00e9t\u00e9 r\u00e9alis\u00e9e \u00e0 l&#039;aide de SPSS (version 22.0, IBM, Armonk, NY, USA) et de GraphPad Prism (version 8.0.2, GraphPad Software, San Diego, CA, USA). La valeur P &lt; 0,05 a \u00e9t\u00e9 consid\u00e9r\u00e9e comme statistiquement significative.<\/p><h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Results\"><\/span><strong>R\u00e9sultats<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p>Au total, 145 patients ont \u00e9t\u00e9 inclus dans cette \u00e9tude. Les donn\u00e9es d\u00e9mographiques de tous les patients sont r\u00e9sum\u00e9es dans le tableau&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Tab1\" rel=\"nofollow noopener\" target=\"_blank\">1<\/a>. Parmi eux, 82 patients ont subi leur premier examen radiographique pour la d\u00e9tection de la scoliose. L'\u00e2ge moyen de tous les patients \u00e9tait de 19,9 \u00b1 8,7 ans (intervalle : 6\u223d39 ans), avec 88 patients \u00e2g\u00e9s de 18 ans ou moins (moyenne : 13,7 \u00b1 2,7 ans, intervalle : 6\u223d18 ans). Les ICC intra- et interobservateurs pour l'angle de Cobb d\u00e9riv\u00e9 du 3D-SSS \u00e9taient respectivement de 0,969 (IC 95% : 0,957-0,977) et de 0,934 (IC 95% : 0,909-0,952), ce qui indique une excellente reproductibilit\u00e9. L'analyse Bland-Altman (Fig.&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a>) a r\u00e9v\u00e9l\u00e9 un biais de 0,1\u00b0 pour les mesures intra-observateur et de - 0,4\u00b0 pour les mesures inter-observateurs. Sept et cinq patients \u00e9taient hors des limites de concordance (LOA) pour les mesures intra-observateur (-4,2\u223d4,4\u00b0) et inter-observateur (-6,6\u223d5,8\u00b0), respectivement. Le RMSE pour la concordance intra- et interobservateur \u00e9tait de 2,1\u00b0 et 3,1\u00b0, respectivement.<\/p><p>L'angle de Cobb moyen mesur\u00e9 par l'EOS et le 3D-SSS \u00e9tait respectivement de 13,7 \u00b1 9,9\u00b0 (intervalle : 0,5\u223d45,7\u00b0) et de 12,5 \u00b1 8,6\u00b0 (intervalle : 0,4\u223d40\u00b0). La diff\u00e9rence absolue de l'angle de Cobb entre l'EOS et le 3D-SSS \u00e9tait de 2,5 \u00b1 2,9\u00b0. La fiabilit\u00e9 des mesures de l'angle de Cobb entre l'EOS et le 3D-SSS \u00e9tait excellente [ICC = 0,921 (95% CI : 0,893\u223d0,943)]. L'analyse de Bland-Altman (Fig.&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Fig4\" rel=\"nofollow noopener\" target=\"_blank\">4<\/a>) a indiqu\u00e9 un biais de -1,171\u00b0 entre l'EOS et le 3D-SSS, 10 patients se situant en dehors de la LOA (-8,3\u223d6,0\u00b0). Le RMSE entre l'EOS et le 3D-SSS \u00e9tait de 3,2\u00b0. L'analyse de corr\u00e9lation de Pearson a montr\u00e9 une tr\u00e8s forte corr\u00e9lation entre les mesures de l'angle de Cobb obtenues \u00e0 l'aide de l'EOS et du 3D-SSS (<em>r<\/em>= 0.931,&nbsp;<em>P<\/em>&lt; 0.001). En outre, les diff\u00e9rences dans les mesures de l&#039;angle de Cobb entre l&#039;EOS et le 3D-SSS augmentaient avec l&#039;augmentation de l&#039;angle de Cobb, allant de 1,5\u00b0 \u00e0 12,7\u00b0 lorsque l&#039;angle de Cobb passait de  45\u00b0 (Fig.&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Fig5\" rel=\"nofollow noopener\" target=\"_blank\">5<\/a>).<\/p><p>Les performances diagnostiques du 3D-SSS pour la scoliose (angle de Cobb \u2265 10\u00b0) sont r\u00e9sum\u00e9es dans le tableau ci-dessous.&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Tab2\" rel=\"nofollow noopener\" target=\"_blank\">2<\/a>. La sensibilit\u00e9, la sp\u00e9cificit\u00e9, la valeur pr\u00e9dictive positive et la valeur pr\u00e9dictive n\u00e9gative de la 3D-SSS pour le diagnostic de la scoliose \u00e9taient respectivement de 87,8%, 92,1%, 93,5% et 85,3%. Parmi les 63 patients ayant un angle de Cobb &lt; 10\u00b0, seuls 5 ont \u00e9t\u00e9 reclass\u00e9s \u00e0 un angle de Cobb de 10\u223d25\u00b0 par le 3D-SSS. La courbe ROC (receiver operating characteristic) a d\u00e9montr\u00e9 la forte capacit\u00e9 pr\u00e9dictive de la 3D-SSS pour la scoliose, avec une aire sous la courbe (AUC) de 0,953 [95% CI : 0,918\u223d0,988,&nbsp;<em>P<\/em>&lt; 0,001] (Fig.&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Fig6\" rel=\"nofollow noopener\" target=\"_blank\">6<\/a>). Chez 61 patients pr\u00e9sentant un angle de Cobb de 10\u223d25\u00b0, 10 ont \u00e9t\u00e9 reclass\u00e9s en angle de Cobb  45\u00b0 en un angle de Cobb de 25\u223d45\u00b0. Les r\u00e9sultats de la reclassification par 3D-SSS sont d\u00e9taill\u00e9s dans le tableau&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#Tab3\" rel=\"nofollow noopener\" target=\"_blank\">3<\/a>. <\/p><figure class=\"wp-block-image\"><a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3\/figures\/4\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/media.springernature.com\/lw685\/springer-static\/image\/art%3A10.1186%2Fs12891-025-08415-3\/MediaObjects\/12891_2025_8415_Fig4_HTML.png\" alt=\"figure 4\"\/><\/a><figcaption class=\"wp-element-caption\"><strong>Fig. 4<\/strong> Analyse Bland-Altman de l'angle de Cobb. (<strong>A<\/strong>) Angle de Cobb entre 3D-SSS et EOS ; (<strong>B<\/strong>) Angle de Cobb de l'accord intra-observateur sur le 3D-SSS ; (<strong>C<\/strong>) Angle de Cobb de l'accord interobservateur sur le 3D-SSS<\/figcaption><\/figure><figure class=\"wp-block-image\"><a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3\/figures\/5\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/media.springernature.com\/lw685\/springer-static\/image\/art%3A10.1186%2Fs12891-025-08415-3\/MediaObjects\/12891_2025_8415_Fig5_HTML.png\" alt=\"figure 5\"\/><\/a><figcaption class=\"wp-element-caption\"><strong>Fig. 5<\/strong> Diff\u00e9rences d'angle de Cobb entre 3D-SSS et EOS<\/figcaption><\/figure><p><strong>Tableau 2 <\/strong>Capacit\u00e9 de diagnostic de la scoliose par 3D-SSS<\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1400\" height=\"214\" src=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65874-1400x214.png\" alt=\"\" class=\"wp-image-7219\" srcset=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65874-1400x214.png 1400w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65874-800x122.png 800w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65874-768x117.png 768w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65874-1536x235.png 1536w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65874-18x3.png 18w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65874-1000x153.png 1000w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65874.png 1564w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><\/figure><figure class=\"wp-block-image\"><a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3\/figures\/6\" rel=\"nofollow noopener\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/media.springernature.com\/lw685\/springer-static\/image\/art%3A10.1186%2Fs12891-025-08415-3\/MediaObjects\/12891_2025_8415_Fig6_HTML.png\" alt=\"figure 6\"\/><\/a><figcaption class=\"wp-element-caption\"><strong>Fig. 6<\/strong> Courbes ROC de la capacit\u00e9 diagnostique du 3D-SSS pour la scoliose<\/figcaption><\/figure><p><strong>Tableau 3 <\/strong>Reclassification de la s\u00e9v\u00e9rit\u00e9 de la scoliose par 3D-SSS<\/p><figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1400\" height=\"364\" src=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65875-1-1400x364.png\" alt=\"\" class=\"wp-image-7253\" srcset=\"http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65875-1-1400x364.png 1400w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65875-1-800x208.png 800w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65875-1-768x200.png 768w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65875-1-1536x400.png 1536w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65875-1-18x5.png 18w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65875-1-1000x260.png 1000w, http:\/\/www.forethoughtmed.com\/wp-content\/uploads\/2025\/03\/\u8bba\u65875-1.png 1560w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><\/figure><h2 class=\"wp-block-heading\" id=\"Sec8\"><span class=\"ez-toc-section\" id=\"Discussion\"><\/span><strong>Discussion<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p>La pr\u00e9sente \u00e9tude a d\u00e9montr\u00e9 que les angles de Cobb d\u00e9riv\u00e9s de la reconstruction automatique de la 3D-SSS \u00e9taient en bon accord avec ceux obtenus par EOS, avec d'excellents ICC intra- et inter-observateurs pour la 3D-SSS. Ces r\u00e9sultats indiquent que le 3D-SSS fournit des mesures fiables et pr\u00e9cises pour les patients atteints de scoliose.<\/p><p>L'angle de Cobb est un param\u00e8tre essentiel pour l'\u00e9valuation du SIA [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR17\" rel=\"nofollow noopener\" target=\"_blank\">17<\/a>]. Actuellement, la radiographie informatis\u00e9e et la radiographie num\u00e9rique sont les m\u00e9thodes les plus courantes pour l'\u00e9valuation quantitative de l'angle de Cobb \u00e0 l'aide de rayons X. Le syst\u00e8me EOS a \u00e9t\u00e9 largement adopt\u00e9 depuis son introduction. Le syst\u00e8me EOS a \u00e9t\u00e9 largement adopt\u00e9 depuis son introduction, sa faisabilit\u00e9 et sa pr\u00e9cision dans l'\u00e9valuation des AIS et de la scoliose adulte ayant \u00e9t\u00e9 confirm\u00e9es par des \u00e9tudes ant\u00e9rieures [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR18\" rel=\"nofollow noopener\" target=\"_blank\">18<\/a>,<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR19\" rel=\"nofollow noopener\" target=\"_blank\">19<\/a>,<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR20\" rel=\"nofollow noopener\" target=\"_blank\">20<\/a>,<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR21\" rel=\"nofollow noopener\" target=\"_blank\">21<\/a>,<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR22\" rel=\"nofollow noopener\" target=\"_blank\">22<\/a>]. La recherche a d\u00e9montr\u00e9 un niveau \u00e9lev\u00e9 de pr\u00e9cision dans les mesures de l'angle de Cobb obtenues \u00e0 partir de l'EOS par rapport \u00e0 la tomodensitom\u00e9trie, \u00e0 la fois dans des \u00e9tudes sur fant\u00f4mes et sur des patients [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR18\" rel=\"nofollow noopener\" target=\"_blank\">18<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR23\" rel=\"nofollow noopener\" target=\"_blank\">23<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR24\" rel=\"nofollow noopener\" target=\"_blank\">24<\/a>]. Par cons\u00e9quent, l'EOS est consid\u00e9r\u00e9 comme l'\u00e9talon-or pour l'\u00e9valuation de la scoliose \u00e0 l'aide de l'angle de Cobb et de la rotation vert\u00e9brale axiale (RVA). Cependant, les jeunes patients AIS soumis \u00e0 une exposition r\u00e9p\u00e9t\u00e9e aux rayons X risquent de subir des dommages dus aux radiations [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR25\" rel=\"nofollow noopener\" target=\"_blank\">25<\/a>].<\/p><p>Cette \u00e9tude a r\u00e9v\u00e9l\u00e9 que les angles de Cobb mesur\u00e9s par le nouveau 3D-SSS portable et sans radiation sont tr\u00e8s coh\u00e9rents avec ceux mesur\u00e9s par l'EOS. Plusieurs facteurs peuvent expliquer cette coh\u00e9rence : (1) La m\u00e9thode de collecte des donn\u00e9es du 3D-SSS refl\u00e8te celle de l'EOS, en capturant simultan\u00e9ment les param\u00e8tres frontaux et lat\u00e9raux de la colonne vert\u00e9brale dans des conditions de port de poids, ce qui refl\u00e8te \u00e9troitement la posture r\u00e9elle du patient dans la vie quotidienne. (2) Le syst\u00e8me utilise un capteur MEMS de haute pr\u00e9cision qui atteint des valeurs de pr\u00e9cision th\u00e9oriques de \u2264 1\u00b0 dans des environnements exempts d'interf\u00e9rences magn\u00e9tiques. (3) Le logiciel de post-traitement fait automatiquement correspondre les donn\u00e9es collect\u00e9es \u00e0 chaque vert\u00e8bre gr\u00e2ce \u00e0 des algorithmes de fusion de capteurs et au contr\u00f4le du filtre de gain, produisant ainsi un mod\u00e8le num\u00e9rique 3D de la colonne vert\u00e9brale tr\u00e8s pr\u00e9cis. (4) Le logiciel de post-traitement traduit la technique standard de mesure de l'angle de Cobb (d\u00e9termination de l'angle entre les corps vert\u00e9braux sup\u00e9rieur et inf\u00e9rieur avec une inclinaison maximale dans un segment de scoliose) en un mod\u00e8le math\u00e9matique de vecteur spatial, automatisant les calculs des param\u00e8tres de la colonne vert\u00e9brale et r\u00e9duisant les erreurs manuelles.<\/p><p>Des \u00e9tudes ant\u00e9rieures ont examin\u00e9 diverses m\u00e9thodes non radiologiques pour la d\u00e9tection de la scoliose et l'\u00e9valuation de l'angle de Cobb. Le scoliom\u00e8tre combin\u00e9 au test d'Adams est une m\u00e9thode manuelle couramment utilis\u00e9e en pratique clinique, mais elle manque d'objectivit\u00e9, de pr\u00e9cision et de r\u00e9p\u00e9tabilit\u00e9 [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR26\" rel=\"nofollow noopener\" target=\"_blank\">26<\/a>]. De m\u00eame, les appareils \u00e9lectroniques portables de d\u00e9pistage de la scoliose utilisent la technologie de d\u00e9tection \u00e9lectronique 3D de la gravit\u00e9 pour mesurer la rotation superficielle du tronc et estimer la gravit\u00e9 de la scoliose, ce qui peut produire des r\u00e9sultats faussement positifs [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR27\" rel=\"nofollow noopener\" target=\"_blank\">27<\/a>]. En outre, Li et al. ont propos\u00e9 une m\u00e9thode d'\u00e9chographie 3D pour \u00e9valuer l'angle de Cobb en utilisant la technologie ultrasonique pour imager les apophyses \u00e9pineuses dorsales du patient et reconstruire la morphologie de la colonne vert\u00e9brale. Leur \u00e9tude a r\u00e9v\u00e9l\u00e9 un coefficient de corr\u00e9lation &gt; 0,75 entre l'angle de Cobb et l'apophyse \u00e9pineuse dorsale, ce qui sugg\u00e8re que les mesures \u00e9chographiques de la s\u00e9quence de l'apophyse \u00e9pineuse peuvent permettre des \u00e9valuations quantitatives de l'angle de Cobb sans radiographie [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR28\" rel=\"nofollow noopener\" target=\"_blank\">28<\/a>]. Toutefois, un mauvais contact entre la sonde et la peau ou un gel de couplage insuffisant peut nuire \u00e0 la transmission du signal ultrasonore, ce qui affecte n\u00e9gativement la pr\u00e9cision de la mesure [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR29\" rel=\"nofollow noopener\" target=\"_blank\">29<\/a>].<\/p><p>Comme dans l'\u00e9tude de Li et al, ce syst\u00e8me utilise l'apophyse \u00e9pineuse dorsale comme point de r\u00e9f\u00e9rence anatomique. Cependant, contrairement aux m\u00e9thodes bas\u00e9es sur les ultrasons qui localisent l'apophyse \u00e9pineuse uniquement par imagerie, ce syst\u00e8me utilise un capteur combin\u00e9 MEMS de haute pr\u00e9cision et une technologie de mesure de la trajectoire dans l'espace de contact. Le module de mesure de l'angle de l'espace de trajectoire et le module de mesure de la distance de trajectoire d\u00e9tectent avec pr\u00e9cision la position vectorielle de chaque apophyse \u00e9pineuse dans l'espace 3D. En outre, les donn\u00e9es de balayage du terrain provenant du balancier optimisent la mesure en tenant compte de l'inclinaison et de la torsion de l'apophyse \u00e9pineuse caus\u00e9es par la tension des muscles dorsaux et du tissu adipeux. Enfin, la cartographie num\u00e9rique des donn\u00e9es, trait\u00e9e par des algorithmes de fusion et de contr\u00f4le du gain, g\u00e9n\u00e8re un mod\u00e8le vert\u00e9bral 3D correspondant \u00e9troitement \u00e0 la colonne vert\u00e9brale du patient, ce qui permet le calcul et l'analyse de l'angle de Cobb [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR30\" rel=\"nofollow noopener\" target=\"_blank\">30<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR31\" rel=\"nofollow noopener\" target=\"_blank\">31<\/a>]. Cette approche, qui combine la localisation vectorielle en 3D et le balayage topographique de l'apophyse \u00e9pineuse dorsale, semble plus efficace que l'\u00e9chographie seule pour localiser l'apophyse \u00e9pineuse coronale et \u00e9valuer l'angle de Cobb.<\/p><p>Les r\u00e9sultats de cette \u00e9tude ont plusieurs implications cliniques. Le SIA se pr\u00e9sente souvent sans sympt\u00f4mes distincts, ce qui accro\u00eet le risque de ne pas \u00eatre diagnostiqu\u00e9 ou de l'\u00eatre tardivement. La d\u00e9tection pr\u00e9coce de la scoliose par l'imagerie permet d'intervenir \u00e0 temps, par exemple en posant une attelle ou en pratiquant une intervention chirurgicale [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR25\" rel=\"nofollow noopener\" target=\"_blank\">25<\/a>]. Bien que l'EOS soit pr\u00e9cis et fiable pour l'\u00e9valuation de la scoliose, son utilisation est limit\u00e9e aux salles d'examen sp\u00e9cialis\u00e9es et n\u00e9cessite l'intervention de radiographes qualifi\u00e9s. L'EOS pr\u00e9sente \u00e9galement des inconv\u00e9nients, notamment des co\u00fbts initiaux \u00e9lev\u00e9s, des dur\u00e9es d'examen relativement longues et une exposition aux rayonnements, ce qui le rend inadapt\u00e9 au d\u00e9pistage \u00e0 grande \u00e9chelle de l'AIS [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR11\" rel=\"nofollow noopener\" target=\"_blank\">11<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR32\" rel=\"nofollow noopener\" target=\"_blank\">32<\/a>]. L'appareil utilis\u00e9 dans cette \u00e9tude, en revanche, est portable, sans rayonnement et rentable. Le co\u00fbt d'installation initial d'un syst\u00e8me EOS est d'environ $509 480, avec un co\u00fbt par balayage de $11,58 [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR32\" rel=\"nofollow noopener\" target=\"_blank\">32<\/a>]. En comparaison, le co\u00fbt d'acquisition du 3D-SSS est d'environ $41 430, et le co\u00fbt par patient est d'environ $4,14, tous deux nettement inf\u00e9rieurs \u00e0 ceux de l'EOS. En outre, cette \u00e9tude a mis en \u00e9vidence la coh\u00e9rence et la corr\u00e9lation entre les mesures obtenues par le 3D-SSS et l'EOS, ainsi que la grande pr\u00e9cision diagnostique du 3D-SSS, ce qui le rend appropri\u00e9 pour le d\u00e9pistage de l'AIS dans les communaut\u00e9s, les \u00e9coles et les \u00e9tablissements de soins primaires. La d\u00e9tection pr\u00e9coce de la scoliose \u00e0 l'aide d'outils tels que les scoliom\u00e8tres permet des interventions non chirurgicales opportunes, telles que le port d'un appareil orthop\u00e9dique, qui peuvent ralentir la progression [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR33\" rel=\"nofollow noopener\" target=\"_blank\">33<\/a>,&nbsp;<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR34\" rel=\"nofollow noopener\" target=\"_blank\">34<\/a>et la chirurgie \u00e0 des stades appropri\u00e9s pour \u00e9viter les complications associ\u00e9es \u00e0 une scoliose avanc\u00e9e [<a href=\"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08415-3#ref-CR35\" rel=\"nofollow noopener\" target=\"_blank\">35<\/a>]. Le nouveau dispositif 3D-SSS permet \u00e9galement de suivre l'\u00e9volution de la maladie et les r\u00e9sultats du traitement, ce qui a des implications en termes de pronostic. En outre, le logiciel de l'appareil fournit des r\u00e9sultats en 10 secondes, ce qui acc\u00e9l\u00e8re le diagnostic clinique et la prise en charge. Par cons\u00e9quent, l'appareil sans rayonnement offre un outil pratique et efficace pour l'\u00e9valuation de la scoliose.<\/p><p>Cependant, l'\u00e9tude pr\u00e9sente certaines limites : (1) La taille de l'\u00e9chantillon \u00e9tait faible, en particulier pour les patients pr\u00e9sentant des d\u00e9formations s\u00e9v\u00e8res de l'angle de Cobb. Les \u00e9tudes futures devraient inclure un plus grand nombre de patients pr\u00e9sentant des d\u00e9formations graves. (2) L'influence du 3D-SSS sur les strat\u00e9gies de traitement clinique n'a pas \u00e9t\u00e9 \u00e9valu\u00e9e. Par exemple, les patients pour lesquels une intervention chirurgicale est recommand\u00e9e sur la base de l'EOS pourraient \u00eatre trait\u00e9s avec une attelle selon la 3D-SSS, ce qui pourrait affecter la correction de la courbe. Inversement, les patients recommand\u00e9s pour l'observation sur la base de l'EOS pourraient \u00eatre surtrait\u00e9s avec une attelle. D'autres \u00e9tudes sont n\u00e9cessaires pour \u00e9valuer les implications cliniques. (3) L'\u00e9tude manquait de donn\u00e9es de suivi, ce qui emp\u00eachait de comparer le m\u00eame patient dans le temps. (4) Seuls deux m\u00e9decins (un radiologue et un orthop\u00e9diste) ont effectu\u00e9 les examens. Les \u00e9tudes futures devraient impliquer plusieurs op\u00e9rateurs afin d'\u00e9valuer la coh\u00e9rence du syst\u00e8me. (5) Bien que des r\u00e9sultats prometteurs aient \u00e9t\u00e9 obtenus avec des patients portant des v\u00eatements fins, les \u00e9tudes futures devraient examiner si les mesures s'am\u00e9liorent avec le contact direct avec la peau.<\/p><h2 class=\"wp-block-heading\" id=\"Sec9\"><span class=\"ez-toc-section\" id=\"Conclusions\"><\/span><strong>Conclusions<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p>En conclusion, le 3D-SSS fournit des \u00e9valuations pr\u00e9cises et reproductibles de la scoliose chez les adolescents et les jeunes adultes, avec des mesures tr\u00e8s coh\u00e9rentes avec l'EOS. Ce syst\u00e8me peut compl\u00e9ter l'EOS et aider les cliniciens \u00e0 diagnostiquer la scoliose rapidement et avec pr\u00e9cision. Cependant, une validation suppl\u00e9mentaire est n\u00e9cessaire pour les patients pr\u00e9sentant des angles de Cobb importants.<\/p><h3 class=\"wp-block-heading\" id=\"abbreviations\"><span class=\"ez-toc-section\" id=\"Abbreviations\"><\/span><strong>Abr\u00e9viations<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p><dfn><strong>3D-SSS<\/strong>:<\/dfn> Syst\u00e8me de d\u00e9tection tridimensionnelle de la colonne vert\u00e9brale<\/p><p><dfn><strong>3D<\/strong>:<\/dfn> Trois dimensions<\/p><p><strong><em>AIS :<\/em><\/strong> Scoliose idiopathique de l'adolescent<\/p><p><strong><dfn>MEMS :<\/dfn> <\/strong>Syst\u00e8me micro-\u00e9lectro-m\u00e9canique<\/p><p><dfn><strong>LED :<\/strong><\/dfn> Diode \u00e9lectroluminescente<\/p><p><dfn><strong>MCU :<\/strong><\/dfn> Unit\u00e9 de microcontr\u00f4leur<\/p><p><dfn><strong>ICC :<\/strong><\/dfn> Coefficient de corr\u00e9lation intraclasse<\/p><p><dfn><strong>RMSE :<\/strong><\/dfn> Erreur quadratique moyenne<\/p><p><dfn><strong>LOA :<\/strong><\/dfn> Limites de l'accord<\/p><p><dfn><strong>ROC :<\/strong><\/dfn> Caract\u00e9ristique d'exploitation du r\u00e9cepteur<\/p><p><dfn><strong>AUC :<\/strong><\/dfn> Surface sous la courbe<\/p><p><dfn><strong>CI :<\/strong><\/dfn> Intervalle de confiance<\/p><p><dfn><strong>IMC :<\/strong><\/dfn> Indice de masse corporelle<\/p><h3 class=\"wp-block-heading\" id=\"Ack1\"><span class=\"ez-toc-section\" id=\"Acknowledgements\"><\/span><strong>Remerciements<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>Sans objet.<\/p><h3 class=\"wp-block-heading\" id=\"contributions\"><span class=\"ez-toc-section\" id=\"Author_Contributions\"><\/span><strong>Contributions des auteurs<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>Tous les auteurs ont lu et approuv\u00e9 le manuscrit final. Hui Wang : r\u00e9daction du travail Fengyun Zhu : acquisition, analyse et interpr\u00e9tation des donn\u00e9es Qiyuan Bao : acquisition, analyse et interpr\u00e9tation des donn\u00e9es Yong Lu : acquisition, analyse et interpr\u00e9tation des donn\u00e9es Fuhua Yan : conception et design du travail Lianjun Du : r\u00e9vision substantielle du travail Le Qin : conception et design du travail, r\u00e9vision substantielle du travail.<\/p><h3 class=\"wp-block-heading\" id=\"author-information\"><span class=\"ez-toc-section\" id=\"Author_information\"><\/span><strong>Informations sur l'auteur<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><h4 class=\"wp-block-heading\" id=\"affiliations\"><strong>Auteurs et affiliations<\/strong><\/h4><ol class=\"wp-block-list\"><li>D\u00e9partement de radiologie, H\u00f4pital Ruijin, \u00c9cole de m\u00e9decine de l'Universit\u00e9 Jiao Tong de Shanghai, n\u00b0 197 Ruijin 2nd Rd, Shanghai, 200025, ChineHui Wang, Yunfeng Zhu, Yong Lu, Fuhua Yan, Lianjun Du &amp; Le Qin<\/li>\n\n<li>D\u00e9partement d'orthop\u00e9die, H\u00f4pital Ruijin, \u00c9cole de m\u00e9decine de l'Universit\u00e9 Jiao Tong de Shanghai, n\u00b0 197 Ruijin 2nd Rd, Shanghai, 200025, ChineQiyuan Bao<\/li><\/ol><h3 class=\"wp-block-heading\" id=\"Fun\"><span class=\"ez-toc-section\" id=\"Funding\"><\/span><strong>Financement<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>Cette \u00e9tude a \u00e9t\u00e9 financ\u00e9e par le National Key R&amp;D Program of China (2023YFC2410704) et la National Natural Science Foundation of China (82171891).<\/p><h3 class=\"wp-block-heading\" id=\"data-availability\"><span class=\"ez-toc-section\" id=\"Data_availability\"><\/span><strong>Disponibilit\u00e9 des donn\u00e9es<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>Les ensembles de donn\u00e9es utilis\u00e9s et analys\u00e9s dans le cadre de la pr\u00e9sente \u00e9tude sont disponibles aupr\u00e8s de l'auteur correspondant sur demande raisonnable.<\/p><h2 class=\"wp-block-heading\" id=\"ethics\"><span class=\"ez-toc-section\" id=\"Declarations\"><\/span><strong>D\u00e9clarations<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><h3 class=\"wp-block-heading\" id=\"FPar1\"><span class=\"ez-toc-section\" id=\"Ethics_approval_and_consent_to_participate\"><\/span><strong>Approbation \u00e9thique et consentement \u00e0 la participation<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>L'approbation \u00e9thique et le consentement ont \u00e9t\u00e9 obtenus aupr\u00e8s du comit\u00e9 d'\u00e9thique de l'h\u00f4pital Ruijin de l'\u00e9cole de m\u00e9decine de l'universit\u00e9 JiaoTong de Shanghai. Le num\u00e9ro de r\u00e9f\u00e9rence est le n\u00b0 (2022)(273). Uniquement si l'\u00e9tude porte sur des sujets humains : Le consentement \u00e9clair\u00e9 \u00e9crit de tous les sujets (patients) ou de leurs tuteurs l\u00e9gaux a \u00e9t\u00e9 obtenu dans le cadre de cette \u00e9tude.<\/p><h3 class=\"wp-block-heading\" id=\"FPar2\"><span class=\"ez-toc-section\" id=\"Consent_for_publication\"><\/span><strong>Consentement \u00e0 la publication<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>Sans objet.<\/p><h3 class=\"wp-block-heading\" id=\"FPar3\"><span class=\"ez-toc-section\" id=\"Competing_interests\"><\/span><strong>Int\u00e9r\u00eats concurrents<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><p>Les auteurs ne d\u00e9clarent aucun int\u00e9r\u00eat concurrent.<\/p><p>Re\u00e7u : 19 mars 2024 \/ Accept\u00e9 : 11 f\u00e9vrier 2025<\/p><p>Publi\u00e9 en ligne : 26 f\u00e9vrier 2025<\/p><h3 class=\"wp-block-heading\" id=\"Bib1\"><span class=\"ez-toc-section\" id=\"References\"><\/span><strong>R\u00e9f\u00e9rences<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3><ul class=\"wp-block-list\"><li>1. Marya S, Tambe AD, Millner PA, Tsirikos AI. Adolescent idiopathic scoliosis : a review of aetiological theories of a multifactorial disease. Bone Joint J. 2022;104:915-21.<\/li>\n\n<li>2. Peng Y, W ang SR, Qiu GX, Zhang JG, Zhuang QY. Progr\u00e8s de la recherche sur l'\u00e9tiologie et la pathogen\u00e8se de la scoliose idiopathique de l'adolescent. Chin Med J. 2020;133:483-93.<\/li>\n\n<li>3. Guo X, Chau WW, Hui-Chan CW, Cheung CS, Tsang WW, Cheng JC. Balance control in adolescents with idiopathic scoliosis and disturbed somatosensory function. Spine. 2006;31(14):e437-40.<\/li>\n\n<li>4. Song XX, Jin LY, Li XF, Qian L, Shen HX, Liu ZD, et al. Effects of low bone mineral status on biomechanical characteristics in idiopathic scoliotic spinal deformity. World Neurosurg. 2018;110:e321-9.<\/li>\n\n<li>5. Konieczny MR, Senyurt H, Krauspe R. Epidemiology of adolescent idiopathic scoliosis. J Child Orthop. 2013;7:3-9.<\/li>\n\n<li>6. Aebi M. La scoliose de l'adulte. Eur Spine J. 2005;14:925-48.<\/li>\n\n<li>7. Cheng JC, Castelein RM, Chu WC, et al. Adolescent idiopathic scoliosis. Nat Rev Dis Primers. 2015;1:15030.<\/li>\n\n<li>8. Weinstein SL, Dolan LA, Spratt KF, Peterson KK, Spoonamore MJ, Ponseti IV. Health and function of patients with untreated idiopathic scoliosis. A 50-year natural history study. JAMA. 2003;289:559-67.<\/li>\n\n<li>9. Dubousset J, Charpak G, Skalli W, Deguise J, Kalifa G. EOS : a new imaging system with low dose radiation in standing position for spine and bone &amp; joint disorders. J Musculoskelet Res. 2010;13:1-12.<\/li>\n\n<li>10. Harada GK, Siyaji ZK, Younis S, Louie PK, Samartzis D, An HS. Imagerie en chirurgie du rachis : concepts actuels et orientations futures. Spine Surg Relat Res. 2019;4:99-110.<\/li>\n\n<li>11. Garg B, Mehta N, Bansal T, Malhotra R. EOS imaging : concept and current applications in spinal disorders. J Clin Orthop Trauma. 2020;11:786-93.<\/li>\n\n<li>12. Luo TD, Stans AA, Schueler BA, Larson AN. Cumulative radiation exposure with EOS imaging compared with standard spine radiographs. Spine Deform. 2015;3:144-50.<\/li>\n\n<li>13. Melhem E, Assi A, El Rachkidi R, Ghanem I. EOS biplanar X-ray imaging : concept, developments, benefits, and limitations. J Child Orthop. 2016;10:1-14.<\/li>\n\n<li>14. Algamili AS, Khir MHM, Dennis JO, et al. A review of actuation and sensing mechanisms in MEMS-based sensor devices. Nanoscale Res Lett. 2021;16:16.<\/li>\n\n<li>15. Sabatini AM. Estimating three-dimensional orientation of human body parts by inertial\/magnetic sensing (Estimation de l'orientation tridimensionnelle des parties du corps humain par d\u00e9tection inertielle\/magn\u00e9tique). Sensors. 2011;11:1489-525.<\/li>\n\n<li>16. Carmi A, Oshman Y. Adaptive particle filtering for spacecraft attitude estimation from vector observations. J Guid Control Dynam. 2009;32:232-41.<\/li>\n\n<li>17. Rigo M. \u00c9valuation du patient dans la scoliose idiopathique : \u00e9valuation radiographique, d\u00e9formation du tronc et asym\u00e9trie du dos. Physiother Theory Pract. 2011;27:7-25.<\/li>\n\n<li>18. Al-Aubaidi Z, Lebel D, Oudjhane K, Zeller R. Three-dimensional imaging of the spine using the EOS system : is it reliable ? A comparative study using computed tomography imaging. J Pediatr Orthop B. 2013;22:409-12.<\/li>\n\n<li>19. Rehm J, Germann T, Akbar M, et al. 3D-modeling of the spine using EOS imaging system : inter-reader reproducibility and reliability. PLoS ONE. 2017;12:1-13.<\/li>\n\n<li>20. Okamoto M, Jabour F, Sakai K, Hatsushikano S, Le Huec JC, Hasegawa K. Sagittal balance measures are more reproducible when measured in 3D vs in 2D using full-body EOS images. Eur Radiol. 2018;28:4570-7.<\/li>\n\n<li>21. Chan AC, Morrison DG, Nguyen DV, Hill DL, Parent E, Lou EH. Intra- and interobserver reliability of the Cobb angle-vertebral rotation angle-spinous process angle for adolescent idiopathic scoliosis. Spine Deform. 2014;2:168-75.<\/li>\n\n<li>22. Kim SB, Heo YM, Hwang CM, et al. Fiabilit\u00e9 du syst\u00e8me d'imagerie EOS pour l'\u00e9valuation de l'alignement de la colonne vert\u00e9brale et du bassin dans le plan sagittal. Clin Orthop Surg. 2018;10:500-7.<\/li>\n\n<li>23. Glaser DA, Doan J, Newton PO. Comparison of 3-dimensional spinal reconstruction accuracy : biplanar radiographs with EOS versus computed tomography. Spine (Phila Pa 1976). 2012;37:1391-7.<\/li>\n\n<li>24. Carreau JH, Bastrom T, Petcharaporn M, et al. Computer-generated, three-dimensional spine model from biplanar radiographs : a validity study in idiopathic scoliosis curves greater than 50 degrees. Spine Deform. 2014;2:81-8.<\/li>\n\n<li>25. Rigo MD, Villagrasa M, Gallo D. A specific scoliosis classification correlating with brace treatment : description and reliability. Scoliosis. 2010;5:1-11.<\/li>\n\n<li>26. Fong DY, Lee CF, Cheung KM, et al. A meta-analysis of the clinical effectiveness of school scoliosis screening. Spine (Phila Pa 1976). 2010;35:1061-71.<\/li>\n\n<li>27. Li C, Zhang B, Liu L, et al. Design, reliability, and validity of a portable electronic device based on ergonomics for early screening of adolescent scoliosis. J Orthop Translat. 2021;28:83-9.<\/li>\n\n<li>28. Li M, Cheng J, Ying M, Ng B, Lam TP, Wong MS. A preliminary study of estimation of Cobb's angle from the spinous process angle using a clinical ultrasound method. Spine Deform. 2015;3:476-82. <\/li>\n\n<li>29. Lai KK, Lee TT, Lee MK, Hui JC, Zheng YP. Validation of scolioscan air-portable radiation-free three-dimensional ultrasound imaging assessment system for scoliosis. Sensors(Basel). 2021;21:2858-75.<\/li>\n\n<li>30. Giansanti D, Macellari V, Maccioni G, Cappozzo A. Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data ? IEEE Trans Biomed Eng. 2003;50:476-83.<\/li>\n\n<li>31. Cortell-Tormo JM, Garcia-Jaen M, Ruiz-Fernandez D, Fuster-Lloret V. Lumbatex : un syst\u00e8me de surveillance portable bas\u00e9 sur des capteurs inertiels pour mesurer et contr\u00f4ler le mouvement de la colonne lombaire. IEEE Trans Neural Syst Rehabil Eng. 2019;27:1644-53.<\/li>\n\n<li>32. Faria R, McKenna C, Wade R, Yang H, Woolacott N, Sculpher M. The EOS 2D\/3D X-ray imaging system : a cost-effectiveness analysis quantifying the health benefits from reduced radiation exposure. Eur J Radiol. 2013;82:342-9.<\/li>\n\n<li>33. Diebo BG, Segreto FA, Solow M, et al. Adolescent idiopathic scoliosis care in an underserved inner-city population : screening, bracing, and patient- and parent-reported outcomes. Spine Deform. 2019;7:559-64.<\/li>\n\n<li>34. Grossman DC, Curry SJ, Owens DK, et al. Screening for adolescent idiopathic scoliosis : US preventive services task force recommendation statement. JAMA. 2018;319:165-72.<\/li>\n\n<li>35. Adobor RD, Rimeslatten S, Steen H, Brox JI. School screening and point prevalence of adolescent idiopathic scoliosis in 4000 Norwegian children aged 12 years. Scoliosis. 2011;6:1-7.<\/li><\/ul><h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Publishers_note\"><\/span><strong>Note de l'\u00e9diteur<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2><p>Springer Nature reste neutre en ce qui concerne les revendications juridictionnelles dans les cartes publi\u00e9es et les affiliations institutionnelles.<\/p><p><strong>Acc\u00e8s libre<\/strong>&nbsp;Cet article est soumis \u00e0 la licence internationale Creative Commons Attribution-NonCommercial-NoDerivatives 4.0, qui autorise l'utilisation, le partage, la distribution et la reproduction \u00e0 des fins non commerciales sur n'importe quel support ou dans n'importe quel format, \u00e0 condition que vous mentionniez de mani\u00e8re appropri\u00e9e l'auteur ou les auteurs originaux et la source, que vous fournissiez un lien vers la licence Creative Commons et que vous indiquiez si vous avez modifi\u00e9 le mat\u00e9riel sous licence. Cette licence ne vous autorise pas \u00e0 partager du mat\u00e9riel adapt\u00e9 d\u00e9riv\u00e9 de cet article ou de parties de celui-ci. Les images ou autres \u00e9l\u00e9ments de tiers figurant dans cet article sont inclus dans la licence Creative Commons de l'article, sauf indication contraire dans la ligne de cr\u00e9dit de l'\u00e9l\u00e9ment. Si le mat\u00e9riel n'est pas inclus dans la licence Creative Commons de l'article et que l'utilisation que vous souhaitez en faire n'est pas autoris\u00e9e par la loi ou d\u00e9passe l'utilisation autoris\u00e9e, vous devrez obtenir l'autorisation directement aupr\u00e8s du d\u00e9tenteur des droits d'auteur. Pour consulter une copie de cette licence, visitez le site&nbsp;<a href=\"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/\" rel=\"nofollow noopener\" target=\"_blank\">http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Wang et al. BMC Musculoskeletal Disorders (2025) 26:200       <br \/>https:\/\/doi.org\/10.1186\/s12891-025-08415-3                                            <\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[121,112,118,119,113,120],"class_list":["post-7150","post","type-post","status-publish","format-standard","hentry","category-blog","tag-cobb-angle","tag-forethought","tag-portable","tag-radiation-free","tag-scoliosis","tag-three-dimensional-spine-sensing-system"],"_links":{"self":[{"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/posts\/7150","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/comments?post=7150"}],"version-history":[{"count":93,"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/posts\/7150\/revisions"}],"predecessor-version":[{"id":7332,"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/posts\/7150\/revisions\/7332"}],"wp:attachment":[{"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/media?parent=7150"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/categories?post=7150"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.forethoughtmed.com\/fr\/wp-json\/wp\/v2\/tags?post=7150"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}